When surmounting trouble rises, an optic fiber technician must choose the most suitable patch panel for a particular situation. That technician must recognize that when it comes to easy installation, proper termination and long term maintenance, not all patch panels are created equally. Optic fiber is robust and therefore deserves some special treatment. For example: if a horizontal copper cable is damaged, one user will be affected. If a backbone fiber goes down, it can take a lot of users down with it. This is why using fully enclosed connecting hardware for optic fiber is crucial. This is where the technician must choose between using wall-mounted or rack-mounted hardware. The optic fiber density required will most likely influence the technicians choice between the wall-mounted and rack-mounted connectivity. Many technicians will choose to use fiber patch cables. Trust your technician to know what’s best.

Wall-mounted enclosures are suitable for up to 24 optic fibers, although with small form factors and high density connectors, can extend the fiber optic cable count to as many as 144. Wall-mount enclosures also offer the benefit of reduced floor space requirements. Rack-mounted optic fiber enclosures can be used with higher fabric counts or depending on the proximity to communications equipment, where rack-mounted optic fiber enclosures are preferable. 1U enclosures can handle up to 24 optic fiber cables with ST or SC connectors, or up to 48 optic fibers by using small form factor connectors. For extra protection, 2U to 4U enclosures can be used to handle up to 144 optic fiber connections.

A 12 fiber MPO connector can speed installation time and increase the concentration of connection hardware. The factory terminated and tested cassettes take care of breaking out the optic fibers from the MPO connectors to ST, SC, or MT-RJ connectors. The MPO cassettes can double the concentration that are possible in rack-mount enclosures - up to 72 optic fibers in a 1U enclosure and 288 optic fibers in a 4U enclosure - making these optic fibers perfectly fit to meet high density applications, such as data center’s and storage area networks.

Accessibility is a concern for long term maintenance when choosing a rack-mount enclosure. The 1U enclosures may have a an access panel to reach the rear optic fibers, while larger enclosures may have a removable rear cover with adequate room inside to make changes or perform repairs. Strain relief and loop management for incoming cables must be provided, nonetheless management devices should be small enough as to not interfere with access to the optic fibers. Cable management for patch cords should be provided on the front of the enclosure with clear front covers and labeling arranged to ease moves, adds and changes and by ensuring that port identification is not obscured by patch cords.

Since copper patch panels need to be strong enough not to flex too much as the cables are punched down. The rolled edges on the panel sheet metal stock help to make the panels rigid. Copper patch panels should provide 24 ports in a 1U height or 48 ports in a 2U height. It's very important to make sure that the modular jacks and circuit traces on the panels are protected from debris that can short out circuits. All cable management systems must be easy to use and maintain to avoid any potential problems.

 

About the Author:

James Croydon, Fiber Network Engineer and Fiber Patch Cables expert - focusing on Fiber Optic Cable and LC Fiber


Read more articles by: James Croydon

Article Source: www.iSnare.com

Ratings
You must be logged in to leave a rating.
Average rating: (0 votes)
Comments

No Comments Yet.


You must be logged in to leave a Comment.
ARTICLES
Control Panels for Identifying Switches and Controls
Control panels are used to identify switches and controls on equipment. May cover membrane switches, and have holes for switches or screws, clear areas for indicator lights, etc. Usually printed on Lexan pr Lexsaver. Because control panels are often subject to physical contact - whether due to use of membrane switches, or due to proximity to connectors and control knobs--the most durable materials are usually used in their construction. For practical purposes, this generally means one of three types of material compositions: Lexan® 10 mil, LexSaver™ or Polyester 2 mil - Gloss White or Clear.
Temperature Control with Solar Panels
While solar energy is most often associated with the production of electricity, heating is also a major platform. Temperature control is the key to an efficient system. Temperature Control with Solar Panels The sun produces a ton of energy, but solar panel systems have historically been very inefficient at converting it. With improving technology, efficiency has improved to the point where most panel systems can easily produce enough energy to heat water for the home and pools. Obviously, controlling the heat production is a key element of this process.
Industrial Touch Screen Monitors
As the name suggests, touch screens are touch sensitive units that are controlled by touching the screen. That means you can manipulate the display with a finger or with a stylus. Touch screen is basically a method of inputting and displaying data from a computer on the same screen.
Pros and Cons of Solar Energy
What are the pros and cons of solar energy? Solar energy is the power of the future and its use is rapidly growing. But is it really that efficient that is could be the answer to the energy crises? Solar energy by itself is not the answer; however it is a major player in the solution.
The Most Important Piece Of Arc Flash Equipment Revealed
Getting the appropriate levels of protection in your workplace environment starts with you and your employer. It is the employer's responsibility to insure that safety procedures are followed and set into place. However, it is also your responsibility as a professional to insure those regulations and policies are followed, maintained, and updated regularly. Arc flash equipment is an important part of your career or occupation if you work around live electricity or stored electricity. One wrong step and you can lose more than your job; you could lose your life.